RE: Steel Composite Design for Positive Moment

$
0
0

Yes composite design will be implemented for the newer version of the AISC code and it would design the sections as non-composite for positive moments. For the AISC 9th edition check, the design is carried out for positive ( non-composite ) and negative moments (composite ) and the one which yields higher utilization ratio is reported as critical.