Hi,
The LY and LZ are effective length of a member to calculate Slenderness Ratio for buckling about local Y axis and Z axis respectively. By default, program considers the member length as the effective length. If the effective length of the member in your model is not same as the original length of the member, you can specify the length using LY and LZ. Go to the design tab > Design parameters to specify these.