Re: Self weight is too much

$
0
0

The property values that you used for the user defined table does not seem to be consistent with the units. Most likely you intended to use MM KN as units for the user table section C125X65X15 instead of METER KN

START USER TABLE

TABLE 2

*UNIT METER KN  - should be replaced by the next line

UNIT MM KN

CHANNEL

C125X65X15

1818 125 5.5 65 9.5 4.66712e+006 786815 43031.5 22.9597 687.5 823.333

Few additional observations

1. Since you have used MEMBER TENSION you should be using REPEAT LOADs as opposed to LOAD COMBINATIONs

2. If you intended to release major and minor axis moments for members, you should release MY MZ as opposed to MX MY.