Blast- Design
The following query has been asked by a STAAD.Pro user:I would like to check with you if anyone at Bentley is familiar with Blast-Resistant design and if anyone has performed Blast-Resistant design...
View ArticleRe: Modeler not installed or is in use
Option 1 did work. The tip of the day and the modeler opened.Thanks very much.
View ArticleRe: Combining Static Loads with Moving Loads
Do you have any pile cap/block present in the actual construction of your structure sir? It seems that you did not incorporate it into your model. Your model would not be the true representation of the...
View ArticleMinor axis capacity mismatch
Query:Design Code: IS 800:2007The Minor axis capacity reported in the STAAD.Pro output does not match with the manual calculation. The data I used are :Section Name: ISMB300Unbraced length of the...
View ArticleRe: Minor axis capacity mismatch
Answer:The overall class of the section is Plastic. If you consider this section class to calculate the minor axis capacity, the capacity is more than the capacity reported in the output. In STAAD.Pro,...
View ArticleHigh-rise building analysis
Query:I need to analyze and design high-rise building with shear walls in STAAD.Pro but analysis of that building takes so much time to run.What is the reason for that?
View ArticleRe: High-rise building analysis
The model contains 6749 nos. of beam elements, 160 nos. of surface elements. If you model a surface element, by default each edge of the surface gets subdivided into 10 parts at the time of analysis....
View ArticleCompatiblity with STAAD.Pro 2006
A STAAD.Pro user writes: Attaching a file. What is to be done to make the file compatible with STAAD.Pro 2006? Errors like empty load cases are being reported when opened in STAAD.Pro 2006.
View ArticleRe: Compatiblity with STAAD.Pro 2006
On a general note there are two aspects to backward compatibility : 1) Syntax changes in input: Every new version of STAAD.Pro comes with a set of new features that are described in the Software...
View ArticleCompression Only Springs experiencing tension.
A STAAD.Pro user asks:"For a model I am running, I need to analyse it with compression only springs. The structure is placed on a trailer on which it has compression-only springs. Besides that, it will...
View ArticleRe: Compression Only Springs experiencing tension.
The supports are experiencing tension for the Load Combination cases.As the structure has Compression-Only spring supports, it is a non-linear case and one should use the “Repeat Load” syntax instead...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
Mr. Sanju,In lieu 0f increasing the ratio to 1.33, it would be better in my view to multiply all the loads of the cmbination containing the seismic load with a factor 3/4. It may serve the purpose....
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
The code is suggesting to increase the allowable stresses induced for the seismic load combination by 33%. If we increase the factor of safety imposed on the load combination and use them in steel...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
The code is suggesting to increase the allowable stresses induced for the seismic load combination by 33%. If we increase the factor of safety imposed on the load combination and use them in steel...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
The code is suggesting to increase the allowable stresses induced for the seismic load combination by 33%. If we increase the factor of safety imposed on the load combination and use them in steel...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
Mr. SanjuActually I have suggested to decrease the facotor of safety to 3/4 (0.75) so that one is not required to assign different ratio for different load case and that ratio of 1.0 would be valid for...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
If we are using Working Stress Method of design, we need to use a load factor of 1. The code is not allowing the designer to use factored load combination.Undser such a condition, we need to check the...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
Mr. Sanju,Code is not prepared based on the options available in the software. Code is giving a guideline. It is for the designer to decide as to how he can achieve the stipulation of the code with the...
View ArticleRe: Can multiple RATIO commands apply to a single Code Check?
Please not the if we are using a code, we should strictly adhere to all the provisions and stipulations of the code. Just in case of WSM, we can not use any kind arbitrary load factors. We must use...
View ArticleSTAAD output warning
Query:I have prepared a STAAD model for designing a central store building. After running the analysis, I found multiple instances of the following error message in the output file. *** WARNING :...
View Article