Whenever I work on Staad Foundation Advanced it closes automatically when I ask to design...
Plz reply with a solution..Thanks in Advance
Staad Foundation Advanced it closes automatically
Shearwall design
How do we analyse and design shear wall in staad ce v22 and rcdc 9.0 using the IS code.The model is prepared in staad ce using the surface option and then imported into rcdc,but does not show up in rcdc as walls.Is there incompatibility.also where to design the strip footing for shear walls in rcdc or staad?
Curved Beams and slabs in staad pro
Hi...
How to design Curved beams and slabs in staad pro??
Thanks in advance
Importing dwg format into Staad.Pro
How to import the dwg format CAD file into staadpro?
How to import it without errors?
Thanks in advance
RAM Concept Error - Cannot connect to Staad.Pro
Hi,
I want to design my Post Tension Slab in RAM Concept after do the analysis using Staad.Pro.
However, I got the warning as per image attached.
.
I use the latest version for both Staad.Pro and RAM Concept
RAM Concept version: 6408010027_update 1
Staad.Pro: 22040040
what should I do to solve this problem?
Modelling a lamp post in FE, P-delta effect
Sent: 08 July 2020 09:13
To: RAMSTAADOpenTower@communities.bentley.com
Cc: Dhanjal Minde
Subject: RE: [RAM | STAAD | OpenTower Forum] Modelling a lamp post in FE, add load on a dummy element to add loads to lamp post.: Suggested Answer
Sent: 07 July 2020 19:43
To: RAMSTAADOpenTower@communities.bentley.com
Subject: RE: [RAM | STAAD | OpenTower Forum] Modelling a lamp post in FE, add load on a dummy element to add loads to lamp post.: Suggested Answer
|
"; font-size: 8.2pt;">***********************************************************************************
"; font-size: 8.2pt;">The contents of this e-mail and any attached files are confidential. If you have received this email in error, please notify us immediately at postmaster@tfl.gov.uk and remove it from your system. If received in error, please do not use, disseminate, forward, print or copy this email or its content. Transport for London excludes any warranty and any liability as to the quality or accuracy of the contents of this email and any attached files.
"; font-size: 8.2pt;">
"; font-size: 8.2pt;">
"; font-size: 8.2pt;">Transport for London is a statutory corporation whose principal office is at 5 Endeavour Square, London, E20 1JN. Further information about Transport for London’s subsidiary companies can be found on the following link: http://www.tfl.gov.uk/corporate/about-tfl/
"; font-size: 8.2pt;">
"; font-size: 8.2pt;">
"; font-size: 8.2pt;">Although TfL have scanned this email (including attachments) for viruses, recipients are advised to carry out their own virus check before opening any attachments, as TfL accepts no liability for any loss, or damage which may be caused by viruses.
"; font-size: 8.2pt;">***********************************************************************************
"; font-size: 8.2pt;">
In staad circular Hollow section are not getting designed as per South African code, can anybody pls tell why?
In staad circular Hollow section are not getting designed as per South African code, can anybody pls tell why?
Node coordinates
How do i view the coordinates of the node apart from viewing it from the node table Thank you.
Basics of staad pro
- Why do we need to set tolerance value while setting a node in diagonals?
Error occur during conversion of physical model to analytical model
- This is the problem I have while converting the physical model to analytical model it come like this what can do to overcome this.
STAAD Foundation Advanced Pilecap with 2 piles message
Two Pile Combination cannot resist transverse moment,hence for shear,punching,BM calculations transverse moment is ignored. So for pile cap parallel to X, Mx=0,Fz=0. And for pile cap parallel to Z, Mz=0,Fx=0.
With this message can we say that the design is ok?
RAM Elements Retaining Wall Rebar
Hello,
I am designing a retaining wall using the module in RAM Elements. I've inputted the longitudinal and transverse reinforcement that I want to use for my retaining wall but am having difficultly with the report result. It tells me that there are warnings in my design and states that "Asmin>Asprov (stem)." So, I went to the stem portion of the report to check it out (photo inserted below) and based off the table, I see that Asreq is 0.4 in^2 whilst Asprov is 0.41in^2 so there should not be a problem there. For the stem transverse reinforcement, the minimum shrinkage and temperature reinforcement is 0.36 in^2 so I don't see a problem there either. Could you please help and clarify why I'm getting this warning?
Thank you.
Analysis of G+6 Residential building
Dear Managers,
I'm Running to Analysis a G+6 Residential Concrete building by using Staad pro and considering Dead load and Live load only. I will be grateful to you provide a sample Pdf format or Staad pro File or the Video Guide.
Member offset consideration in Model
Dear Experts.
What does it mean Member offset Command Consideration in Model?
Wind Loads on Open Structures with Angle Sections
I'm looking for some help in understanding how STAAD's wind loads are applied to Open Structures, specifically those constructed of angle-section members.
In this thread from several years ago, Kris Sathia stated the following:
For wind load on single angles in OPEN type of structures, the load intensity (force per unit length of the member) is calculated in the following manner.
If a beta angle is specified, the program finds the exposed width as sqrt(L*L+W*W) where L and W are the dimensions of the legs. This term multiplied by the wind pressure gives the magnitude of the distributed load on the member and is applied as a projected load acting in the direction of that global axis.
If a beta angle is not specified, the load intensity is equal to the dimension of the larger leg multiplied by the load intensity, and applied as a projected load.
This explanation is very counter-intuitive to me. Yet I confirmed with a test model that it works as described.
Consider, if I add an equal-leg angle member without beta angle to a model, it will typically be oriented such that it's maximum projected width is normal to one of the global wind directions. The maximum projected width of unequal-leg angles would not be far from perpendicular as well. Yet STAAD uses only the width of the larger leg to determine area, not the maximum width from sqrt(L*L+W*W).
In contrast, if I add an angle with beta angle, it's likely that I'm adjusting the orientation to be "square with the world", having legs that are horizontal and vertical. Thus, one of the angle legs (we could assume the larger of the two) is likely to be normal to an applied wind load. However, in this case STAAD uses the maximum width from sqrt(L*L+W*W), even though one leg is likely to contribute very little area.
Is there an explanation for why this works backwards from how it seems it should be? Am I misunderstanding something? Thanks in advance for any advise or suggestions.
Ram Concept - Determine the stress for every point in a span
Hi,
Following are some questions I would like to ask,
1. May I know how to determine the stresses at top and bot stress plan of every point in a span? Is there any table or command that i can see the detailed stresses because the result show the maximum value of stresses for top and bot stresses.
2. May I know what is the yellow circle numbers mean in diagram attached below?
3. How to turn off the yellow circle number?
Thank you.
Offset Command for concrete structures
Whether it is necessary to use offset Command in beam to combine the beam properly with column ?
Whether There will be any change in deflection / Load transfer mechanism associated with offset beam and non offset beam?
What are the uses of offset Command?
Thanks in advance
What are the units of the api?
Hi,
I'm using the function GetNodeCoordinates from the StaadPro Connect edition API, it gives the results in inches. Does it always give the results in inches? Even if the units of the model are something else like N-cm?
No bottom bars on beam design, and constant beam failure
Hi!
I need some advice. Strangely enough, when I run my STAAD Model on the RC Designer, I keep getting these errors on my beams:
1. Insufficient torsion reinforcement at [segment of beam]
2. Anchorage requirements not met.
Additionally, I find it really strange that the reinforcements of my beams are always at the top? No bottom bars, just top bars. Can anyone offer some help? Thanks a lot!
Generating Mesh in Plates
Hi...
I am willing to know that can we generate a mesh in a Plate (a wooden platform resting on many primary and secondary steel beams)?
The attached picture is an example of my question. In drawing 1 we can see that ABCD is a square plate connected to Nodes A, B, C, and D. - In this case, the load applied on the Plate will directly be transferred to points ABCD but that load may not be transferred to the intermediate steel beams.
In order to make the load gets a transfer to intermediate beams, can I generate a mesh in ABCD plate that splits a big plate into the smaller mesh and connects to all the intermediate / secondary beams? This will also split the beam into smaller members. Will that affect the analysis results?
Can I generate any number of smaller mesh from a plate?
Your response is highly appreciated.
Thanks