RE: STAAD FDN ADVANCED - SAMPLE COMB FOOT 4 - UNABLE TO VALIDATE - FOOTING FAILED IN SLIDING CHECK IN X DIR

$
0
0

I believe there is a bug in the Combined foundation Toolkit mode. It works when there is no shear force (FX/FZ) but as soon as i give even an insignificant value (say 1kN) to FX or FZ, the design fails. Also there is no safety factor defined for sliding.